Canadian codes require dwelling units to be separated to a minimum of STC 50, or alternatively ASTC 47 under the option introduced in the 2015 National Building Code. Meeting it is mandatory. Exceeding it is what makes a suite comfortable and rentable — and the reason so many code-compliant suites still sound bad is flanking: sound travelling around the separation rather than through it.
- The requirement: STC 50, or ASTC 47 as an alternative that accounts for flanking
- STC rates the assembly. ASTC rates what people actually hear — the more honest measure
- Most disappointing suites fail on flanking paths, not on the wall or floor itself
- The worst offenders: ducts, plumbing stacks, the shared stairwell and rim joists
- This is the one item we’d tell you not to economise on
Sound separation is a code requirement, and it’s also the single item that most determines whether your tenants renew and whether you can live comfortably above them. Those two facts pull in the same direction, which is unusual — so it’s worth doing properly.
What the code requires
Canadian building codes require a minimum standard of sound separation between dwelling units. Two compliance routes exist.
STC 50 — the traditional metric. Sound Transmission Class 50 has been the requirement between dwellings since 1990. STC is measured in a laboratory and describes the performance of the separating assembly alone — the wall or floor as tested.
ASTC 47 — the alternative added in the 2015 National Building Code. Apparent Sound Transmission Class accounts for sound travelling through adjoining construction and common building elements, not just through the separating assembly. Because it captures flanking paths, it’s a considerably better description of what occupants actually hear.
Why two numbers for the same thing? Because a wall tested at STC 50 in a laboratory frequently performs worse in a real building — sound gets around it. ASTC 47 is a lower number describing a more demanding real-world test. The 2015 change was an acknowledgement that laboratory ratings had been over-promising.
What the ratings mean in plain terms. At around STC 50, normal speech from the adjoining unit should be inaudible or barely audible; loud speech may be faintly heard but not understood. Bass, footfall and impact noise are a different matter — STC measures airborne sound, and it doesn’t capture someone walking across the floor above you.
That gap between the rating and the experience is the whole subject. Meeting code and having a quiet suite are related but not the same, and the difference is mostly flanking.
Where sound actually travels
If your separation performs worse than its rating suggests, the sound is going around it. The usual paths, in rough order of how much trouble they cause:
1. Ducts. A shared heating system is a direct acoustic connection between the units — conversation travels along ductwork remarkably well. Separating the heating systems entirely is often the cleanest solution, and it also simplifies the fire separation and gives each unit independent control. Where ducts must cross, lined ducts and offsets help.
2. Plumbing stacks. A drain stack running through both units carries every flush. Wrapping the stack in mass-loaded material and isolating it from framing addresses most of it — and it’s cheap while walls are open, and expensive afterwards.
3. The shared stairwell. Where both units open onto a common landing, the stairwell becomes a shared acoustic volume. Solid-core doors help — and Alberta requires them anyway, at 45 mm minimum with self-closers — plus weatherstripping and a threshold seal, which do as much for sound as for smoke.
4. Rim joists and the wall-to-floor junction. The perimeter where the floor assembly meets the exterior wall is a continuous flanking path around the separation. It’s fiddly, it’s usually detailed last, and it’s a common weak point.
5. Electrical boxes and pot lights. Back-to-back outlets in a separating wall are holes in it. Offsetting boxes and using acoustic putty pads costs almost nothing at rough-in.
6. Impact noise from above. Footfall, dropped objects, chair legs. STC doesn’t measure it and a code-compliant floor can still transmit it badly. Resilient channel, floating floors and carpet or good underlay all help.
The practical point: money spent closing flanking paths usually buys more perceived quiet than money spent upgrading the main assembly. Most people do it the other way round.
Assemblies that work
In general terms. Confirm specifics with your designer, because ratings attach to tested assemblies — substituting a component can invalidate the rating.
Walls between units commonly use decoupling: staggered or double studs so the two faces don’t share framing, cavity insulation, and multiple layers of gypsum board. Resilient channel on one face achieves much of the same effect more cheaply, provided it’s installed correctly — it’s frequently short-circuited by screws driven through into the framing, which eliminates the benefit entirely.
Floor/ceiling assemblies between a basement suite and the dwelling above are the substantial item. Typical approaches combine cavity insulation, resilient channel or sound clips on the ceiling side, and additional gypsum layers. Mass and decoupling are the two levers.
What helps most, in order:
- Decoupling — breaking the structural connection between the two sides
- Mass — more layers of board
- Absorption — insulation in the cavity
- Sealing — every gap, penetration and edge
And a genuinely useful overlap: many of these measures also serve the fire separation, which is required anyway. Resilient channel, cavity insulation and multiple board layers appear in both conversations. Design the two together rather than sequentially and you’ll spend less than doing them separately.
Retrofit vs new build
In new construction, this is straightforward and cheap. Decoupled framing, proper insulation, sealed penetrations and separated ducts cost very little at the framing stage. There’s no excuse for a poorly separated new suite.
In a retrofit, it depends entirely on what’s already there — and the honest answer is that doing it well means opening up the ceiling.
That’s why sound separation is where conversion budgets get quietly cut. The finished basement is already there, the ceiling is already up, and adding a layer beneath it looks like a reasonable compromise. It usually isn’t: without addressing the cavity, the framing connection and the flanking paths, additional board on the underside delivers far less than expected.
The sequencing point that saves money: you’re opening the ceiling for fire separation anyway in most conversions. Do the acoustic work at the same time. Doing it later means opening it twice.
Cost
We don’t publish a figure — it scales with the area of shared assembly and with how much has to be opened up.
What drives it:
- The area of separation — a suite under the whole footprint costs more than one under part of it
- Whether existing finishes come down. In a finished basement this is most of the cost
- Duct separation — often the single most effective spend
- Decoupling method — resilient channel is cheaper than double framing and nearly as effective when installed correctly
- Impact noise treatment, if you’re addressing footfall as well as airborne sound
The framing that matters more than the number: sound separation is usually a modest addition to work you’re already doing, and a large expense if retrofitted afterwards. The decision point is whether to do it properly while the ceiling is open — and the answer is essentially always yes.
Why it affects rent and turnover
The commercial argument, which is stronger than most owners assume.
Sound is the most common complaint in shared-building living, and it’s the one tenants can’t design around. A tenant who hears every footstep doesn’t renew.
Turnover is expensive. Vacancy between tenants, cleaning, advertising, showings, and the risk of a worse tenant next time. One avoided turnover generally covers a lot of acoustic work.
It affects achievable rent. A quiet suite shows better and lets faster. It doesn’t photograph — which is exactly why it’s under-invested in — but a prospective tenant standing in a suite while someone walks around upstairs notices immediately.
And you live with it too. In a basement conversion, you’re above the tenant. Poor separation is a daily irritation for both households, and it’s the thing most likely to make an owner regret the project.
Our view: of all the code items in a suite conversion, this is the one where meeting the minimum is the weakest strategy. Exceeding it is comparatively cheap while the ceiling is open, and it pays back in tenure length rather than in rent. Our how it works page covers how these decisions fit the build sequence.
Plan the separation before the ceiling closes
Sound and fire separation are the same construction event. Doing them together while assemblies are open is the difference between a suite people stay in and one they leave.
HouseLyft’s free property assessment establishes what your conversion involves and where the cost drivers sit. Our secondary suites overview covers the category and our FAQ answers common questions. Request your free report.